1.1 seismic precautionary intensity
The seismic intensity approved as the basis for seismic fortification of a region in accordance with the authority prescribed by the state. In general, the seismic intensity with a probability of exceeding 10% within 50 years is taken.
1.2 Seismic precautionary criterion
The scale for measuring seismic fortification requirements is determined by the seismic fortification intensity or design ground motion parameters and building fortification category.
1.3 earthquake action
The dynamic effects of structures caused by ground motions include horizontal and vertical earthquakes.
1.4 building mechanical and electrical equipment engineering facilities
Auxiliary machinery, electrical construction, components and systems that serve the building use functions. It mainly includes elevators, lighting systems and emergency power supplies, communication equipment, plumbing systems, heating and air conditioning systems, fire alarm and fire fighting systems, and shared antennas.
1.5 seismic support
A component composed of anchor solids, reinforced booms, diagonal braces and seismic connection components.
1.6 seismic bracing
It is firmly connected with the building structure and uses seismic force as the seismic support facility for the load. It is composed of anchors, reinforced booms, seismic connection members and seismic braces.
1.7 Lateral seismic bracing
Seismic support and hanger with diagonal brace parallel to the pipe cross section.
1.8 Longitudinal seismic bracing
Seismic support and hanger with diagonal brace perpendicular to the pipe cross section.
1.9 Single tube (rod) seismic bracing single tube seismic bracing
An earthquake-resistant support and hanger composed of a load-bearing hanger and an earthquake-resistant diagonal brace.
1.10 door-shaped seismic bracing door-shaped seismic bracing
There are two or more load-bearing hangers, beams, and seismic braces composed of seismic supports and hangers.
1.11 Design basic acceleration of ground motion
The design value of the seismic acceleration with a probability of exceeding 10% during the 50-year design base period.
1.12 Design characteristic period of ground motion
The seismic influence coefficient curve used for seismic design reflects the period value corresponding to the starting point of the descending section of factors such as earthquake magnitude, epicenter distance, and site category.